Actual outside diameter and Schedule 10 / 40 / 80 wall thickness for nominal pipe sizes 1/8″ through 2″ per ASME B36.10. Scoped to the small-bore instrument and process range — for larger pipe sizes, use a full B36.10 table.

NPS, OD and wall by schedule

NPSActual OD (in)OD (mm)Sch 10 wall (in)Sch 40 wall (in)Sch 80 wall (in)
1/80.40510.290.0490.0680.095
1/40.54013.720.0650.0880.119
3/80.67517.150.0650.0910.126
1/20.84021.340.0830.1090.147
3/41.05026.670.0830.1130.154
11.31533.400.1090.1330.179
1-1/41.66042.160.1090.1400.191
1-1/21.90048.260.1090.1450.200
22.37560.330.1090.1540.218

How to use this chart

The NPS name is not a measurement: read the actual OD from this table, then pick the wall by schedule — Schedule 40 matches the STD wall and Schedule 80 matches XS in these sizes. Schedule changes the wall, not the OD. Dimensions are the published ASME B36.10 nominal values; the standard and the mill certificate govern for procurement.